Articles

Sort By:  
The Use of Tourniquets in the Russo-Ukrainian War

Samarskiy IM, Khoroshun EM, Vorokhta Y 24(1). 67 (Journal Article)

Aim: The objective of the study was to evaluate the use of tourniquets in the Russo-Ukrainian war. Methods: The type, number, and duration of tourniquets per limb, the clinical course of limb injuries, and the functional status of the injured limbs during the 24 hours post-injury were evaluated in military hospital facilities for the period of 2014-2022. Statistical frequencies and variances were analyzed. Results: During active hostilities, the medical units of the Southern Operational Command received 2,496 patients with limb injuries that required the application of tourniquets. Lower extremity injuries were predominantly observed (84.4%). A single tourniquet was used in 1,538 cases (61.6%), whereas two tourniquets were used in 533 (21.4%), and three tourniquets in 425 cases (17.0%). During the 2014- 2021 period, Esmarch's tourniquet was most commonly used. However, in 2022, it was mostly replaced by the Combat Application Tourniquet and similar systems (e.g., Sich, Dnipro). The duration of the tourniquet use ranged from 50 to 380 minutes (mean 205.9 [standard error 8.1] min), which prolonged ischemia in a significant number of cases. Limb amputations, mainly due to extensive necrosis, were performed in 92 cases (3.7%). In addition to 101 deaths (4.0% of patients), 11 cases of severe tourniquet syndrome were encountered. The limb was salvaged in 9 cases (81.8%). Conclusion: Prompt triage and evacuation of injured combatants can save affected limbs, even when the duration of tourniquet use exceeds 2 hours. Tourniquet syndrome can be prevented using a hemostatic tourniquet.

$43.00
Prescreened Whole O Blood Group Walking Blood Bank Capabilities for Nontraditional Maritime Medical Receiving Platforms: A Case Series

Chang R, Boyle BP, Udoh MO, Maestas JM, Gehrz JA, Ruano E, Banker L, Cap AP, Bitterman JW, Deaton TG, Auten JD 24(1). 60 (Journal Article)

Background: Tactical Combat Casualty Care (TCCC) guidelines recognize low-titer group O whole blood (LTOWB) as the resuscitative fluid of choice for combat wounded. Utilization of prescreened LTOWB in a walking blood bank (WBB) format has been well described by the Ranger O low-titer blood (ROLO) and the United States Marine Corps Valkyrie programs, but it has not been applied to the maritime setting. Methods: We describe three WBB experiences of an expeditionary resuscitative surgical system (ERSS) team, attached to three nontraditional maritime medical receiving platforms, over 6 months. Results: Significant variations were identified in the number of screened eligible donors, the number of LTOWB donors, and the timely arrival at WBB activation sites between the platforms. Overall, 95% and 84% of the screened eligible group O blood donors on the Arleigh Burke Class Destroyer (DDG) and Nimitz Class Aircraft Carrier (CVN), respectively, were determined to be LTOWB. However, only 37% of the eligible screened group O blood donors aboard the Harper's Ferry Class Dock Landing Ship (LSD) were found to be LTOWB. Of the eligible donors, 66% did not complete screening, with 52% citing a correctable reason for nonparticipation. Conclusion: LTOWB attained through WBBs may be the only practical resuscitative fluid on maritime platforms without inherent blood product storage capabilities to perform remote damage control resuscitation. Future efforts should focus on optimizing WBBs through capability development, education, and training efforts.

$43.00
When Minutes Matter: A Comparison of Whole Blood Collection Techniques

Wier R, Walther S, Woodard C, Jordan CS, Matthews KJ, Deaton TG, Drew B, Byrne T, Zarow GJ 24(1). 53 (Journal Article)

Background: Fast and reliable blood collection is critical to emergency walking blood banks (WBB) because mortality significantly declines when blood is quickly administered to a warfighter with hemorrhagic shock. Phlebotomy for WBB is accomplished via either the "straight stick" (SS) or "ruggedized lock" (RL) method. SS comprises a 16-gauge phlebotomy needle connected to a blood collection bag via tubing. The RL device collects blood through the same apparatus, but has a capped, intravenous (IV) catheter between the needle and the donor's arm. This is the first study to compare these two methods in battlefield-relevant metrics. Methods: Military first responders and licensed medical providers (N=86) were trained in SS and RL as part of fresh whole blood training exercises. Outcomes included venipuncture success rates, time to IV access, blood collection times, total time, and user preferences, using a within-subjects crossover design. Data were analyzed using ANOVA and nonparametric statistics at p<0.05. Results: SS outperformed RL in first venipuncture success rates (76% vs. 64%, p=0.07), IV access times (448 [standard error of the mean; SE 23] vs. 558 [SE 31] s, p<0.01), and blood collection bag fill times (573 [SE 48] vs. 703 [SE 44] s, p<0.05), resulting in an approximate 3.5-minute faster time overall. Survey data were mixed, with users perceiving SS as simpler and faster, but RL as more reliable and secure. Conclusion: SS is optimal when timely collection is imperative, while RL may be preferable when device stability or replacing the collection bag is a consideration.

$43.00
Heat Tolerance Testing and the Return to Duty Decision: A Two-Year Case Cohort Analysis

Kester R, Abraham PA, Leggit JC, Harp JB, Kazman JB, Deuster PA, O'Connor FG 24(1). 48 (Journal Article)

Background: Among individuals with prior exertional heat illness (EHI), heat tolerance testing (HTT) may inform risk and return to duty/activity. However, little is known about HTT's predictive validity, particularly for EHI recurrence. Our project sought to demonstrate the predictive validity of HTT in EHI recurrence and HTT's utility as a diagnostic tool in exertional heat stroke (EHS). Methods: Participants with prior EHS were recruited for the study by a physician's referral and were classified as heat tolerant or intolerant after completing demographics and an HTT. Participants were further categorized as single/simple (SS) EHI or recurrent/complex (RC) EHI by conducting a retrospective record review of the following two years. We calculated the positive (PPV) and negative predictive values (NPV) of HTT. Results: The retrospective review of HTT records was used to categorize 44% of Servicemembers as RC, with 77% classified as heat tolerant, 14% as heat intolerant, and 9% as borderline. When borderline cases were classified as heat intolerant, HTT had a high NPV, indicating a high probability that heat-tolerant individuals did not have recurrent EHI. When borderline cases were classified as heat tolerant, NPV and sensitivity decreased while specificity increased. Conclusion: We demonstrated that the HTT had a 100% NPV for future EHI over two years of follow-up for Servicemembers with a history of recurrent heat injury and negative HTT results. An HTT can provide critical data points to inform return to duty decisions and timelines by predicting the risk of EHI recurrence.

$43.00
Emergency Fresh Whole Blood Transfusion Training for Ukrainian Health Professionals in Austere Environments

Brown ZL, Cuestas JP, Matthews KJ, Shumaker JT, Moore DW, Cole R 24(1). 38 (Journal Article)

Background: Blood is a highly valuable medical resource that necessitates strict guidelines to ensure the safety and well-being of the recipient. Since the onset of the war in Ukraine there has been an increased demand for training in emergency fresh whole blood transfusion (EFWBT) to improve damage control resuscitation capabilities. To meet this demand, we developed, implemented, and evaluated a training program aimed at enhancing Ukrainian EFWBT proficiency. Methods: Eight Ukrainian healthcare professionals (UHPs), including six physicians and two medics, completed our training, derived from the Joint Trauma System Clinical Practice Guidelines, Tactical Combat Casualty Care (TCCC) Guidelines, 75th Ranger Regiment Ranger O-Low Titer (ROLO) program, and Marine Corps Valkyrie program. Participants were assessed on their confidence in the practical application and administrative oversight requirements of an EFWBT program. A cross-comparison was conducted between a larger data set of third-year medical students from the Uniformed Services University and the UHPs to determine the statistical significance of the program. Results: The difference in mean scores of UHPs during preand post-training was statistically significant (p<0.001). Additionally, the average rate of improvement was greater for the UHPs compared with the third-year medical students (p=0.000065). Conclusion: Our study revealed that the application of an EFWBT training program for UHPs can significantly increase confidence in their ability to conduct EFWBTs on the battlefield. Further larger-scale research is needed to determine the impact of this training on performance outcomes.

$43.00
Life Over Limb: Why Not Both? Revisiting Tourniquet Practices Based on Lessons Learned From the War in Ukraine

Patterson J, Bryan RT, Turconi M, Leiner A, Plackett TP, Rhodes LL, Sciulli L, Donnelly S, Reynolds CW, Leanza J, Fisher AD, Kushnir T, Artemenko V, Ward KR, Holcomb JB, Schmitzberger FF 24(1). 18 (Journal Article)

The use of tourniquets for life-threatening limb hemorrhage is standard of care in military and civilian medicine. The United States (U.S.) Department of Defense (DoD) Committee on Tactical Combat Casualty Care (CoTCCC) guidelines, as part of the Joint Trauma System, support the application of tourniquets within a structured system reliant on highly trained medics and expeditious evacuation. Current practices by entities such as the DoD and North Atlantic Treaty Organization (NATO) are supported by evidence collected in counter-insurgency operations and other conflicts in which transport times to care rarely went beyond one hour, and casualty rates and tactical situations rarely exceeded capabilities. Tourniquets cause complications when misused or utilized for prolonged durations, and in near-peer or peer-peer conflicts, contested airspace and the impact of high-attrition warfare may increase time to definitive care and limit training resources. We present a series of cases from the war in Ukraine that suggest tourniquet practices are contributing to complications such as limb amputation, overall morbidity and mortality, and increased burden on the medical system. We discuss factors that contribute to this phenomenon and propose interventions for use in current and future similar contexts, with the ultimate goal of reducing morbidity and mortality.

$43.00
Development and Implementation of a Standard Operating Procedure for Military Working Dog Blood Collection, Storage, and Transport

Evernham EL, Fedeles BT, Knuf K 24(1). 28 (Journal Article)

Military working canines are critical assets and force multipliers for the Joint Force. Most often deployed forward of Role 2 assets, they are reliant on non-veterinary resources when wounded, ill, or injured in an operational environment. Hemorrhagic shock is the most prevalent form of shock seen in battlefield injuries and is most effectively treated with whole blood transfusion. Dogs cannot be transfused with human blood and there is no formal Department of Defense (DoD) canine blood product distribution system to operational settings. A walking blood bank is helpful when multiple dogs are geographically co-located and the resource can be provided to an injured patient quickly. In areas as widely dispersed as the Horn of Africa, the likelihood of co-location is slim and delaying this vital resource can mean the difference between life and death. Therefore, personnel at the Role 2 facility in Camp Lemonnier, Djibouti, filled a critical capability gap for the operational area by producing a local canine whole blood bank with distribution to multiple countries. This protocol can be replicated by other locations to improve medical readiness for the working canines who serve to maintain DoD Force Protection.

$43.00
Warning: Tourniquets Risk Frostbite in Cold Weather

Kragh JF, O'Conor DK 23(1). 9 (Journal Article)

We sought to better understand the frostbite risk during first-aid tourniquet use by reviewing information relevant to an association between tourniquet use and frostbite. However, there is little information concerning this subject, which may be of increasing importance because future conflicts against near-peer competitors may involve extreme cold weather environments. Historically, clinical frostbite cases with tourniquet use occurred in low frequency but in high severity when leading to limb amputation. The physiologic response of vasoconstriction to cold exposure leads to limb cooling and causes a reduction of limb blood flow, but cold-induced vasodilation ensues as periodic fluctuations that increase blood flow to hands and feet. In animal experiments, tourniquet use increased the development of frostbite. Evidence from human experiments also supports an association between tourniquet use and frostbite. Clinical guidance for caregiving to casualties at risk for frostbite with tourniquet use had previously been provided but slowly and progressively dropped out of documents. Conclusions: The cause of frostbite was deduced to be a sufficiently negative heat-transfer trend in local tissues, which tourniquet use may worsen because of decreasing tissue perfusion. An association between tourniquet use and frostbite exists but not as cause and effect. Tourniquet use increased the risk of the cold causing frostbite by allowing faster cooling of a limb because of reduced blood flow and lack of cold-induced vasodilation. Care providers above the level of the lay public are warned that first-aid tourniquet use in low-temperature (<0°C [<32°F]) environmental conditions risks frostbite.

$43.00
Occlusion Pressures of Tactical Pneumatic Tourniquet 2"

Wall P, Buising CM, Eernisse D, Rentschler T, Winters C, Renner CH 99(5). 0 (Journal Article)

Background: The Tactical Pneumatic Tournqiuet 2" (TPT2, 5.1cm-wide deflated) allows total average applied pressure measurement, which should be useful toward development of emergency-use limb tourniquet certification devices. Methods: The TPT2 hand bulb was replaced with stopcocks and syringes, allowing filling with continuous pressure measurement. Forearm and mid-thigh applications involved two sets of five Doppler-based pulse gone/return pairs. Second set pulse gones were chosen a priori for occlusion pressures (preliminary work indicated greater consistency in second sets). Results: All 68 forearms occluded (30 female, 38 male, median circumference 17.8cm, range 14.6-23.5cm; median second set of pulse gone tourniquet pressures 176mmHg, range 128-282mmHg). Fifty-five thighs occluded (median circumference 54.3cm, range 41.6-62.4cm; median systolic pressure 126mmHg, range 102-142mmHg; median second set of pulse gone pressures 574mmHg, range 274-1158mmHg). Thirteen thigh applications were stopped without occlusion because of concerning pressures combined with no indication of imminent occlusion and difficulties forcing more air into the TPT2 (3 female, 10 male, peak pressures from 958-1377mmHg, median 1220mmHg, p<.0001 versus occluded thighs; median circumference 63.3cm, range 55.0-72.9cm, p<.0001 versus occluded thighs; median systolic pressure 126mmHg, range 120-173mmHg, p<.019 versus occluded thighs). Thigh TPT2 impression widths on five subjects after occlusion were as follows: 3.5cm, occlusion 274mmHg; 2.8cm, occlusion 348mmHg; 2.9cm, occlusion 500mmHg; 2.8cm, occlusion 782mmHg; 2.7cm, occlusion 1114mmHg. Conclusions: Though probably useful to tourniquet certification, the required pressures for thigh occlusion make the TPT2 undesirable for any clinical use, emergency or otherwise.

$43.00
Effects of Tourniquet Features on Application Processes Times

Wall P, Buising CM, White A, Jensen J, Davis J, Renner CH 99(5). 0 (Journal Article)

Background: We investigated emergency-use limb tourniquet design features effects on application processes (companion paper) and times to complete those processes (this paper). Methods: Sixty-four appliers watched training videos then each applied all eight tourniquets: Combat Application Tour- niquet Generation 7 (CAT7), SOF™ Tactical Tourniquet-Wide Generation 3 (SOFTTW3), SOF™ Tactical Tourniquet-Wide Generation 5 (SOFTTW5), Tactical Mechanical Tourniquet (TMT), OMNA Marine Tourniquet (OMT), X8T-Tourniquet (X8T), Tactical Ratcheting Medical Tourniquet (Tac RMT), and RapidStop Tourniquet (RST). Application processes times were captured from videos. Results: From "Go" to "touch tightening system" was fastest with clips and self-securing redirect buckles and without strap/redirect application process problems (n, median seconds: CAT7 n=23, 26.89; SOFTTW3 n=11, 20.95; SOFTTW5 n=16, 20.53; TMT n=5, 26.61; OMT n=12, 25.94; X8T n=3, 18.44; Tac RMT n=15, 30.59; RST n=7, 22.80). From "touch tightening system" to "last occlusion" was fastest with windlass rod systems when there were no tightening system understanding or mechanical problems (seconds: CAT7 n=48, 4.21; SOFTTW3 n=47, 5.99; SOFTTW5 n=44, 4.65; TMT n=38, 6.21; OMT n=51, 6.22; X8T n=48, 7.59; Tac RMT n=52, 8.44; RST n=40, 8.02). For occluded, tightening system secure applications, from "touch tightening system" to "Done" was fastest with self-securing tightening systems tightening from a tight strap (occluded, secure time in seconds from a tight strap: CAT7 n=17, 14.47; SOFTTW3 n=22, 10.91; SOFTTW5 n=38, 9.19; TMT n=14, 11.42; OMT n=44, 7.01; X8T n=12 9.82; Tac RMT n=20, 6.45; RST n=23, 8.64). Conclusions: Suboptimal processes in- crease application times. Optimal design features for fast, occlusive, secure tourniquet applications are self-securing strap/ redirect systems with an easily identified and easily used clip and self-securing tightening systems.

$43.00
3D-Printed Tourniquets Used at the Battlefront in Ukraine: A Pilot Study

Melau J, Bergan-Skar P, Callender N, Rognhaug M, Bekkestad E 99(5). 0 (Journal Article)

Background: The war in Ukraine urged a need for prompt deliv- erance and resupply of tourniquets to the front. Producing tour- niquets near the battlefront was a feasible option with respect to resupply and cost. Methods: A locally produced 3D-printed tourniquet (Ukrainian model) from the "Tech Against Tanks" charity was tested against commercially available and Committee of Tactical Combat Casualty Care (CoTCCC)- recommended tourniquets (C-A-T™ and SOF™TT-W). We tested how well the tourniquets could hold pressure for up to 2 hours. Results: A Kruskal-Wallis test revealed significant differences between the groups (p<.05). Post-hoc testing revealed a signif- icant difference between the C-A-T and the Ukrainian tourni- quet (p=.004). A similar significance was not found between the SOF™TT-W Wide and the Ukrainian model (p=.08). Dis- cussion: The Ukrainian model can hold pressure as well as the commercially available tourniquets. There is much value if this can be produced close to the battlefield. Factors including lo- gistics, cost, and self-sufficiency are important during wartime. Conclusion: We found that our sample of 3D-printed tourni- quets, currently used in the war in Ukraine, could maintain pressure as well as the commercially available tourniquets. In- deed, our tests demonstrated that it could maintain a signifi- cantly higher pressure.

$43.00
Effects of Tourniquet Features on Application Process Times

Wall P, Buising CM, White A, Jensen J, Davis J, Renner CH 99(5). 0 (Journal Article)

Background: We investigated emergency-use limb tourniquet design features effects on application processes (companion paper) and times to complete those processes (this paper). Methods: Sixty-four appliers watched training videos then each applied all eight tourniquets: Combat Application Tour- niquet Generation 7 (CAT7), SOF™ Tactical Tourniquet-Wide Generation 3 (SOFTTW3), SOF™ Tactical Tourniquet-Wide Generation 5 (SOFTTW5), Tactical Mechanical Tourniquet (TMT), OMNA Marine Tourniquet (OMT), X8T-Tourniquet (X8T), Tactical Ratcheting Medical Tourniquet (Tac RMT), and RapidStop Tourniquet (RST). Application processes times were captured from videos. Results: From "Go" to "touch tightening system" was fastest with clips and self-securing redirect buckles and without strap/redirect application process problems (n, median seconds: CAT7 n=23, 26.89; SOFTTW3 n=11, 20.95; SOFTTW5 n=16, 20.53; TMT n=5, 26.61; OMT n=12, 25.94; X8T n=3, 18.44; Tac RMT n=15, 30.59; RST n=7, 22.80). From "touch tightening system" to "last occlusion" was fastest with windlass rod systems when there were no tightening system understanding or mechanical problems (seconds: CAT7 n=48, 4.21; SOFTTW3 n=47, 5.99; SOFTTW5 n=44, 4.65; TMT n=38, 6.21; OMT n=51, 6.22; X8T n=48, 7.59; Tac RMT n=52, 8.44; RST n=40, 8.02). For occluded, tightening system secure applications, from "touch tightening system" to "Done" was fastest with self-securing tightening systems tightening from a tight strap (occluded, secure time in seconds from a tight strap: CAT7 n=17, 14.47; SOFTTW3 n=22, 10.91; SOFTTW5 n=38, 9.19; TMT n=14, 11.42; OMT n=44, 7.01; X8T n=12 9.82; Tac RMT n=20, 6.45; RST n=23, 8.64). Conclusions: Suboptimal processes in- crease application times. Optimal design features for fast, occlusive, secure tourniquet applications are self-securing strap/ redirect systems with an easily identified and easily used clip and self-securing tightening systems.

$43.00
Effects of Tourniquet Features on Application Processes

Wall P, Buising CM, Jensen J, White A, Davis J, Renner CH 99(5). 0 (Journal Article)

Background: We investigated emergency-use limb tourniquet design features effects on application processes (this paper) and times to complete those processes (companion paper). Methods: Sixty-four appliers watched training videos and then each applied all eight tourniquets: Combat Application Tourniquet Generation 7 (CAT7), SOF™ Tactical Tourniquet-Wide Generation 3 (SOFTTW3), SOF™ Tactical Tourniquet-Wide Generation 5 (SOFTTW5), Tactical Mechanical Tourniquet (TMT), OMNA Marine Tourniquet (OMT), X8T tourniquet (X8T), Tactical Ratcheting Medical Tourniquet (Tac RMT), and RapidStop™ Tourniquet (RST). Application processes were scored from videos. Results: Thirty-three appliers had no prior tourniquet experience. All 512 applications were placed proximal to the recipient's simulated distal thigh injury. Thirty-one appliers (13 with no experience) had 66 problem-free applications (18 by no experience appliers). Tightening-system mechanical problems were more frequent with windlass rod systems (26 losing hold of the rod, 27 redoing rod turns, and 58 struggling to secure the rod) versus ratchet systems (3 tooth skips and 16 advance failures). Thirty-five appliers (21 with no experience) had 68 applications (45 by no experience appliers) with an audible Doppler pulse when stating "Done"; causes involved premature stopping (53), inadequate strap pull (1 SOFTTW3, 1 RST), strap/redirect understanding problem (1 SOFTTW5, 1 X8T, 4 Tac RMT, 1 RST), tightening-system understanding problem (2 CAT7, 1 SOFTTW3, 1 TMT, 1 RST), and physical inability to secure (1 SOFTTW3). Fifty-three appliers (32 no experience) had 109 applications (64 by no experience appliers) not correctly secured. Six involved strap/redirect understanding problems: 4 Tac RMT, 1 X8T, 1 SOFTTW5; 103 involved improper securing of non-self-securing design features: 47 CAT7 (8 strap, 45 rod), 31 TMT (17 strap, 19 rod), 22 OMT (strap), and 3 SOFTTW3 (rod). Conclusion: Self-securing systems have process advantages. Because most emergent tourniquet recipients require transport, we believe tourniquet security is a critical design aspect. Decisions regarding tourniquet choices may become very different when both occlusion and tourniquet security are considered.

$43.00
Association of Physical Domain Participation with POTFF Domains in Special Forces Operators

Nelson T, Youngblade L, Goldberg P, Bricker D, Werth K, Riesberg JC, Surrett GW 99(5). 0 (Journal Article)

Background: The purpose of this study was to evaluate the effectiveness of the physical domain (PD) to improve performance in all the POTFF domains (physical, psychological, social/family, and spiritual) among Special Forces (SF) Operators. Methods: This was a cross-sectional study of active SF Operators assigned to the United States Army Special Operations Command (USASOC). Recruitment began in October 2016. Testing began on 1 January 2017, and concluded on 28 February 2020. Participants completed physical testing, blood draws, and questionnaires to determine domain metrics. Means, medians, and proportions were compared by level of participation in the PD. Results: A total of 231 Soldiers participated; n=63 in the control group, n=93 in the <4 days PD/week (PD <4) group, and n=66 in the >4 days PD/week (PD ≥4) group. The average age was 31 years (range 21-47 y). The average time in the Special Operations Forces (SOF) was 4 years (range 0-19 y). The PD ≥4 group showed significantly greater overall upper (p=.01) and lower (p=0) body strength, power (p=.01), and positive affect (p=.04). The PD ≥4 group also had significantly lower anxiety (p=.03), stress (p=.04), and depression (p=.02) than the control group. Conclusion: The PD and psychological domain metrics were most associated with PD participation. This finding is consistent with the goals of the PD, which are to increase physical and mental capabilities and decrease injury recovery time.

$43.00
Effectiveness of Sternal Intraosseous Device in Patients Presenting with Circulatory Shock: A Retrospective Observational Study

Hynes A, Murali S, Bass GA, Kheirbek T, Qasim Z, George N, Yelon JA, Chreiman KC, Martin ND, Cannon JW 99(5). 0 (Journal Article)

Background: Hemorrhagic shock requires timely administration of blood products and resuscitative adjuncts through multiple access sites. Intraosseous (IO) devices offer an alternative to intravenous (IV) access as recommended by the massive hemorrhage, A-airway, R-respiratory, C-circulation, and H-hypothermia (MARCH) algorithm of Tactical Combat Casualty Care (TCCC). However, venous injuries proximal to the site of IO access may complicate resuscitative attempts. Sternal IO access represents an alternative pioneered by military personnel. However, its effectiveness in patients with shock is supported by limited evidence. We conducted a pilot study of two sternal-IO devices to investigate the efficacy of sternal-IO access in civilian trauma care. Methods: A retrospective review (October 2020 to June 2021) involving injured patients receiving either a TALON® or a FAST1® sternal-IO device was performed at a large urban quaternary academic medical center. Baseline demographics, injury characteristics, vascular access sites, blood products and medications administered, and outcomes were analyzed. The primary outcome was a successful sternal-IO attempt. Results: Nine males with gunshot wounds transported to the hospital by police were included in this study. Eight patients were pulseless on arrival, and one became pulseless shortly thereafter. Seven (78%) sternal-IO placements were successful, including six TALON devices and one of the three FAST1 devices, as FAST1 placement required attention to Operator positioning following resuscitative thoracotomy. Three patients achieved return of spontaneous circulation, two proceeded to the operating room, but none survived to discharge. Conclusions: Sternal-IO access was successful in nearly 80% of attempts. The indications for sternal-IO placement among civilians require further evaluation compared with IV and extremity IO access.

$43.00
Bluetooth Tactical Headsets Improve The Speed of Accurate Patient Handoffs

Stinner D, McEvoy C, Broussard MA, Nikolaus AD, Parker CH, Santana H, Karnopp JM, Patel JA 99(5). 0 (Journal Article)

Background: The Committee on En Route Combat Casualty Care recently ranked the patient handoff as their fourth research priority. Bluetooth technology has been introduced to the battlefield and has the potential to improve the tactical patient handoff. The purpose of this study is to compare the traditional methods of communication used in tactical medical evacuation by Special Operations medical personnel (radio push-to-talk [PTT] and Tactical Medic Intercom System [TM-ICS]) to Bluetooth communication. Methods: Twenty-four simulated tactical patient handoffs were performed to compare Bluetooth and traditional methods of communication used in tactical medical evacuation. Patient scenario order and method of communication were randomized. Accuracy and time required to complete the patient handoff were determined. The study took place using a rotary-wing aircraft kept at level 2 to simulate real-world background noise. Preferred method of communication for each study participant was determined. Results: There were no differences in accuracy of the received patient handoffs between groups or patient handoff transmission times at the ramp of the aircraft. However, when comparing patient handoff times to the medical team within the aircraft, Bluetooth communication was significantly faster than both TM-ICS and radio PTT, while Bluetooth PTT and radio PTT were also significantly faster than TM-ICS. Bluetooth communication was ranked as the preferred method of handoff by all study participants. Conclusion: The study demonstrated that utilization of Bluetooth technology for patient handover results in faster handoffs compared with traditional methods without sacrificing any accuracy in a scenario with high levels of noise.

$43.00
Time for the Department of Defense to Field Video Laryngoscopy Across the Battlespace

Schauer S, Long B, Fisher AD, Stednick PJ, Bebarta VS, Ginde AA, April MD 99(5). 0 (Editorial)

$43.00
Unconventional Resilience: An Operational Model

Jeschke EA, Baker JB, Wyma-Bradley J, Dorsch J, Huffman SL 99(5). 0 (Journal Article)

This is the third of nine planned papers drawn from the findings of our ethnographic study entitled "The Impact of Catastrophic Injury Exposure on Resilience in Special Operations Surgical Teams." Building from our strategic framework, this paper will establish that resilience is better understood as cohesive adaptation within a Special Operation Forces (SOF) cultural ecosystem. Exploring unconventional resilience as the inter-relationship across the organization, team, and individual, we will use qualitative quotes to describe the ecosystem of dynamic freedom of maneuver in ambiguity. To achieve our goals, we will: 1) compare conventional and unconventional resilience to operationalize the components of our strategic framework; 2) use qualitative quotes to show how the ecosystem of unconventional resilience functions at each level supporting our operational model; and 3) describe how the operational model of unconventional resilience links to tactical performance through five social determinants. We conclude by gesturing to how transformational change-agency applies to practical performance of all SOF medics.

$43.00
A Brief Primer on the Concept of the Neuroweapon for U.S. Military Medical Personnel

Washington M, Dinh DT, Ibarra C, Kua SC 99(5). 0 (Journal Article)

The malevolent application of neuroscience is an emerging threat to the U.S. military. At present, U.S. military medical personnel are not capable of adequately diagnosing or treating the injuries and illnesses that may result from exposure to potential neuroweapons. This fact was illustrated in 2016 when U.S. diplomats serving in Havana, Cuba reported hearing strange noises accompanied by a constellation of unexplained health effects. Similar incidents have been reported in China and Russia. Although various hypotheses have been put forward to explain these symptoms, none of them have been verified. The reported symptoms were analogous to the physiological responses that have been produced in the laboratory by exposing volunteers to pulsed microwave energy. However, these incidents of undetermined origin demonstrate that widespread neurological illness can be disruptive to U.S. government operations and that it is currently not possible to identify the cause, determine the correct treatment, or ascribe attribution to potential neuroweapon use in an overseas setting. Since it is likely that Special Operations medical personnel will be among the first to respond to neuroweapon attacks in the deployed environment, it is essential that they be made aware of this emerging threat and that efforts be made to incorporate potential directed energy neuroweapons and other neuroweapon configurations into future Chemical, Biological, Radiological, Nuclear, and high yield Explosives (CBRN-E) training modules. The intention of this article is to introduce the concept of the neuroweapon to military medical personnel and to provide a brief review of the relevant literature.

$43.00
Effects of Airway Localization Device Use During Surgical Cricothyrotomy on Procedural Times and Confidence Levels of Pre-Hospital Personnel

Schlocker C, Grosser S, Spaulding C, Beltrech B, Brady R 99(5). 0 (Journal Article)

This study evaluated the effect of an airway localization device (ALD) on surgical cricothyrotomy (SC) success rates and prehospital provider confidence. SC is indicated in 0.62% to 1.8% of all patients with military trauma, especially those presenting with traumatic airway obstruction. The effect of ALD was evaluated in an airway mannequin model during SC with the Committee on Tactical Combat Casualty Care (CoTCCC)-recommended Control-Cric Cricothyrotomy System. Outcomes included procedural time, Likert measures of operator confidence, and qualitative data/feedback for suggested future improvements in device design and training. The average procedural times of the hospital corpsmen (HM) including 20 men and 8 women were 67 seconds (without ALD) and 87 seconds (with ALD) respectively, which were statistically significant. Provider confidence for all SC procedural steps increased significantly after SC with and without ALD. The average procedural times of the Navy Special Operations Forces (SOF) group comprising 8 males were 56 seconds (without ALD) and 64 seconds (with ALD), which was not statistically significant. Provider confidence for two SC procedural steps (adequate hook retraction and first-attempt SC tube insertion) increased significantly after SC with and without ALD. First-attempt SC success rates were 90% in each group. Both groups provided feedback on the Control-Cric and ALD, with qualitative feedback analyzed for further SC training recommendations. Procedural times were increased with ALD when compared to those without ALD, although the increase may not be clinically significant in this classroom setting.

$43.00
Per Page      41 - 60 of 1054